LIGHTING REBATES

Energy Efficiency > Business > Rapid > Lighting

 

Click the links below for information on:

   > Fluorescent

   > High Performance Fluorescent

   > Low Watt Fluorescent

   > Permanent Lamp Removal

   > High-Bay and High Output Replacing HID

   > T5 Replacing T12

   > Compact Fluorescent

   > High Intensity Discharge (HID)

   > Other Measures

   > Sensors and Controls

 

   > Lighting Printer Friendly Version (PDF)


* Rebates apply only to new equipment being used to replace existing equipment or as part of a retrofit project.

Fluorescent Lighting
  • Rebates are for replacement or retrofit equipment only
  • Only complete (lamp + ballast), hard-wired or permanently mounted, UL-listed systems qualify
  • T8 ballasts must be < .78 BF (excludes high-bay fixtures)
  • Exterior installations do not qualify
Measure Rebate
Replacing T12 only per fixture
T8 - 8 foot 1 lamp $5.00
T8 - 8 foot 2 lamp $7.00
T8 - 4 foot 4 lamp $5.00
T8 - 4 foot 3 lamp $4.00
T8 - 4 foot 2 lamp $2.50
T8 - 4 foot 1 lamp $1.50
T8 - 3 foot 4 lamp $8.00
T8 - 3 foot 3 lamp $5.00
T8 - 3 foot 2 lamp $3.00
T8 - 3 foot 1 lamp $2.00
T8 - 2 foot 4 lamp $5.00
T8 - 2 foot 3 lamp $4.00
T8 - 2 foot 2 lamp $3.00
T8 - 2 foot 1 lamp $2.00

 

High Performance Fluorescent Lighting
  • Rebates are for replacement or retrofit equipment only
  • Only complete (lamp + ballast), hard-wired or permanently mounted, UL-listed systems qualify
  • HPT8 ballasts must be < .78 BF (excludes high-bay fixtures)
  • Exterior installations do not qualify
  • Must contain high lumen (>3100 initial lumens), F32T8 lamps. System must contain CEE certified ballast.  Read CEE requirements.
Measure Rebate Rebate
  Replacing T12 Replacing T8
HPT8 - 4 foot 1 lamp

$6.00

$4.00
HPT8 - 4 foot 2 lamp $8.00 $6.00
HPT8 - 4 foot 3 lamp $12.00 $10.00
HPT8 - 4 foot 4 lamp $16.00 $12.00
Low Watt Fluorescent Lighting
  • Rebates are for replacement or retrofit equipment only
  • Only complete (lamp + ballast), hard-wired or permanently mounted, UL-listed systems qualify
  • HPT8 ballasts must be < .78 BF (excludes high-bay fixtures)
  • Exterior installations do not qualify
  • System must contain CEE certified ballast and lamps of 28W or less. Read CEE requirements.
Measure Rebate Rebate
  Replacing T12 Replacing T8
Low Watt T8 - 4 foot 1 lamp $6.50 $4.50
Low Watt T8 - 4 foot 2 lamp $9.00 $7.00
Low Watt T8 - 4 foot 3 lamp $13.50 $11.50
Low Watt T8 - 4 foot 4 lamp $18.00 $14.00

Back to Top

 

Permanent Lamp Removal
  • Permanent lamp removal can be claimed if completed project results in a net reduction in the quantity of lamps.
  • De-lamping requires removal of T12 lamps/ballasts and unused lampholders from existing fixtures without replacing the lamps.
  • The total number of lamps claimed for de-lamping cannot be more than the number of replacement lamps installed.
Measure Rebate
De-lamping T12 - 2 foot lamp $4.00/lamp
De-lamping T12 - 3 foot lamp $5.00/lamp
De-lamping T12 - 4 foot lamp $6.00/lamp
De-lamping T12 - 8 foot lamp $9.00/lamp

Back to Top


High-Bay and High Output Lighting Replacing HID
Measure Rebate
Replacing HID systems only per fixture
T8 - High-Bay 4 foot 3 lamp $20.00
T8 - High-Bay 4 foot 4 lamp $25.00
T8 - High-Bay 4 foot 6 lamp $35.00
T8 - High-Bay 4 foot 8 lamp $40.00
T8 HO- 8 foot 1 lamp $10.00
T8 HO- 8 foot 2 lamp $14.00
T5 HO - High-Bay 2 lamp $30.00
T5 HO - High-Bay 3 lamp $40.00
T5 HO - High-Bay 4 lamp $50.00
T5 HO - High-Bay 6 lamp $60.00
T5 HO - High-Bay 8 lamp $75.00

 

T5 Lighting Replacing T12
  • Must use high-temp ballasts for T5 HO
Measure Rebate
Replacing T12 only per fixture
T5 HO - 1 lamp $6.00
T5 HO - 2 lamp $9.00
T5 HO - 3 lamp $11.00
T5 HO - 4 lamp $13.00
T5 - 1 lamp $5.00
T5 - 2 lamp $8.00
T5 - 3 lamp $10.00
T5 - 4 lamp $12.00

Back to Top

 

CFL Lighting
  • CFLs must be Energy Star rated
Measure Rebate
Replacing incandescent fixtures/bulbs per fixture
CFL Pin-Based Fixture $20.00/fixture
CFL Screw In Bulb up to 32 Watss $2.00/bulb
CFL Screw In Bulb > 32 Watts $5.00/bulb

Back to Top



High Intensity Discharge (HID) Lighting
  • Must use an electronic ballast and pulse-start metal halide (PSMH) or ceramic metal halide (CMH) lamp
  • Screw-in retrofit lamps and exterior fixtures are not applicable
Measure Rebate
per fixture
Pulse-Start or Ceramic Metal-Halide 0-100 watts $35.00
Pulse-Start or Ceramic Metal-Halide 100-250 watts $40.00
Pulse-Start or Ceramic Metal-Halide > 250 watts $50.00
Metal-Halide Track Lighting $75.00


Other Measures
Measure Rebate
per sign
LED Traffic Signal — Red $25.00
LED Traffic Signal — Green $50.00
LED Pedestrian Don't Walk Sign $25.00
LED Exit Signs $5.00


Sensors and Controls
  • All sensors must control a minimum of 125 watts
  • The control system must turn off at least half of the lamps in the fixture, or must provide for continuous or step (bi-level) dimming
  • Rebates apply to only one lighting control per space being controlled
  • Maximum rebate of $2,500 for each type of lighting control
  • Occupancy sensors must be passive infrared (PIR) and/or ultrasonic
  • Sensors must use programmable rapid start ballasts
Measure Rebate
Ceiling-Mounted Occupancy Sensor $30.00/sensor
Wall- or Fixture-Mounted Occupancy Sensor $15.00/sensor
Remote-Mounted Daylight Dimming Sensor $60.00/sensor
Fixture-Mounted Daylight Dimming Sensor $30.00/sensor
Dimmable Ballast for Use with Daylight Sensors $40.00/ballast
Central Lighting Control $0.04/connected watt
Switching Controls for Multilevel Lighting $0.04/connected watt
Back to Top

 